iConverter GX/TM2
Jellemzők
- Carrier-Grade optical Ethernet Network Interface Device
- Integrated SNMPv1, SNMPv2c, SNMPv3 and IP-less 802.3ah management
- 802.3ah Link OAM for early fault detection and performance monitoring
- VLAN with 802.1ad Q-in-Q for E-Line and E-LAN services
- Quality of Service for Voice/Data/Video over Ethernet
- Bandwidth control (rate limiting) with 64Kb increments
- Port MIB statistics and optical performance statistics to support Service Level Agreements
- Port Access Control for enhanced security
- 10,240 byte Jumbo frames
- Layer 2 Control Protocol (L2CP) Policy Control
- Configurable Link Fault Propagation modes
- Small Form Pluggable (SFP) transceivers with Optical Statistics for standard or CWDM applications
- Fixed-fiber connectors available for multimode and single-mode dual fiber and single-mode single-fiber
- UTP auto-crossover and auto-negotiation of data rate, duplex modes and pause capabilities
- Commercial (0 to 50ºC), wide (-40º to 60ºC) and extended (-40º to 75º C) temperature ranges
- MEF 9 and 14 Certified Compliant
- NEBS Level 3 Compliant
Alkalmazás
The iConverter GX/TM2 conforms to the Ethernet in the First Mile (EFM) fiber standards to support Fiber-to-the-X Metropolitan and Enterprise LAN networks. The GX/TM2 provides intelligent, securely managed service demarcation at the customer premises, offering Quality of Service and enhanced Bandwidth Control (rate-limiting) capabilities. The GX/TM2 features built-in Operations, Administration and Maintenance (OAM) with comprehensive performance monitoring, fault detection and provisioning.
The GX/TM2 is available as a compact standalone unit or as a chassis plug-in module. The hot-swappable GX/TM2 plug-in module can be mounted in a 19 or 5-Module chassis with any combination of redundant AC and DC power supplies. It can also be mounted in a 2-Module AC or DC powered chassis, or in a 1-Module chassis with AC or DC power input.
The plug-in module can manage other modules in the same chassis and operate as a managed 10/100/1000 media converter. It features two Gigabit Ethernet backplane ports for connectivity to adjacent modules in a chassis for multi-port and multi-service configurations.
The standalone GX/TM2 is available as a tabletop or wall-mount unit. The tabletop model can be DIN-rail mounted using an optional DIN-rail mounting kit. Both the tabletop and the wall-mount models are DC powered and are available with an external AC/DC power adapter or a terminal connector for DC power. The GX/TM2 standalone unit combines management capability with a compact chassis for deployment at the demarcation point.
Carrier-Grade Optical Ethernet
iConverter fiber access Network Interface Devices and media converters are MEF 9 and 14 certified compliant and NEBS Level 3 compliant. iConverter NIDs enable Carrier-Grade Optical Ethernet with reliability and performance monitoring to support Service Level Agreements (SLAs). The modular design of iConverter fiber access equipment future-proofs Metro Ethernet services with scalability of network services and lowers operating costs with comprehensive OAM management and provisioning. |
Metro Ethernet Access
At the Central Office, the GX/TM2 plug-in module is installed in a managed iConverter 19-Module chassis for high-density fiber distribution from UTP switch equipment. At Customer Premises 1 and 2, GX/TM2 standalone NIDs provide a fiber uplink to a single copper port for intelligent demarcation of Ethernet services.
Paraméterek
Description | 10/100/1000BASE-T UTP to 1000BASE-X Fiber Media Converter and Network Interface Device |
Protocols | 10BASE-T, 100BASE-TX, 1000BASE-T, 1000BASE-X with 10,240 bytes max. frame size |
UTP Cable | EIA/TIA 568A/B, Category 5 and higher |
Fiber Cables | Multimode: 50/125, 62.5/125, 100/140μm Single-mode: 9/125μm |
Serial Cable | RS-232, 22 to 24 AWG, 12 to 50 pF/ft. |
UTP Connector | RJ-45 |
Fiber Connectors - SFP - Dual Fiber - Single-Fiber |
LC SC, ST, LC, MT-RJ SC |
Serial Connector | Mini DIN-6 female, mini DIN-6 male to DB-9 female adapter included |
Controls | DIP-Switches and LEDs |
DC Power | Plug-In Module: 1.1A @ 3.3VDC Standalone: 8-15VDC, 0.6A @ 9VDC |
DC Power Connector | Plug-In: Power supplied by backplane Standalone: 2.5mm Barrel Connector or Field-wireable Terminal Connect |
AC Power Adapter [US] |
Plug-In Module: N/A Standalone: 100-120VAC/60Hz 0.06A @ 120VAC |
AC Power Adapter [Universal] | Plug-In Module: N/A Standalone: 100-240VAC/50-60Hz 0.06A @ 120VAC |
Dimensions | Plug-In Module: W:0.85" x D:4.5" x H:2.8" Standalone: W:3.1" x D:4.8" x H:1.0" Wallmount: W:3.8" x D:4.8" x H:1.0" |
Weight without power adapter |
Plug-In Module: 8oz. Standalone: 1 lb. |
Weight with power adapter |
Plug-In Module: N/A Standalone: 1.5 lb. |
Compliance | UL, CE, FCC Class A, MEF 9, MEF 14 |
IP-Based Management | Telnet; SNMPv1, SNMPv2c, SNMPv3 |
Temperature | Standard Operating: 0 to 50º C Wide Operating: -40 to 60º C Extended Operating: -40 to 75 º C Storage: -40 to 80º C |
Humidity | 5 to 95% (non-condensing) |
Altitude | -100m to 4000m |
MTBF (Hours) | Plug-In Module: 450,000 Standalone without Power Adapter: 450,000 Standalone With Power Adapter: 250,000 |
Fiber Type / Dual Fiber or Single-Fiber | Distances | Connector Type | Tx λ (nm) | Rx λ (nm) | Min. Tx Power (dBm) | Max. Tx Power (dBm) | Min. Rx Sense (dBm) | Max. Rx Sense (dBm) | Link Budget (dBm) | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|
SC | MT-RJ | LC | SFP | |||||||||
SFP | - | - | - | - | 8939N-0 | - | - | - | - | - | - | - |
MM/DF | 220/550m | 8922N-0 | 8924N-0 | 8926N-0 | - | 850 | 850 | -10 | -4 | -17 | -3 | 7 |
SM/DF | 12km | 8923N-1 | 8925N-1 | 8927N-1 | - | 1310 | 1310 | -9.5 | -3 | -19.5 | -3 | 10 |
SM/DF | 34km | 8923N-2 | - | 8927N-2 | - | 1310 | 1310 | -5 | 0 | -23 | -3* | 18 |
SM/DF | 80km | 8923N-3 | - | 8927N-3 | - | 1550 | 1550 | -5 | 0 | -23 | -3* | 18 |
SM/DF | 110km | 8923N-4 | - | 8927N-4 | - | 1550 | 1550 | 0 | 5 | -24 | -3** | 24 |
SM/DF | 140km | 8923N-5 | - | 8927N-5 | - | 1550 | 1550 | 2 | 5 | -28 | -8*** | 30 |
SM/SF | 20km | 8930N-1 | - | - | - | 1310 | 1550 | -9.5 | -3 | -20 | -3 | 10.5 |
SM/SF | 40km | 8930N-2 | - | - | - | 1310 | 1550 | -3 | 0 | -20 | -3* | 17 |
SM/SF | 20km | 8931N-1 | - | - | - | 1550 | 1310 | -9.5 | -3 | -20 | -3 | 10.5 |
SM/SF | 40km | 8931N-2 | - | - | - | 1550 | 1310 | -3 | 0 | -20 | -3* | 17 |
SM/SF | 20km | 8932N-1 | - | - | - | 1310 | 1490 | -9.5 | -3 | -20 | -3 | 10.5 |
SM/SF | 20km | 8933N-1 | - | - | - | 1490 | 1310 | -9.5 | -3 | -20 | -3 | 10.5 |
When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other.
*A minimum of 3dB of attenuation is required for these models.
**A minimum of 8dB of attenuation is required for this model.
***A minimum of 13dB of attenuation is required for this model.
When ordering a Wide Temperature model, add a "W" to the end of the part number, and when ordering an Extended Temperature model, add a "Z" to the end of the part number (see chart above).
Chassis and Mounting Options Ordering Table
19-Module | 5-Module | 2-Module | 1-Module | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Configuration | AC (60 watts) | AC (120 watts) | 24VDC | 48VDC | AC | 24VDC | 48VDC | AC | 18-60DC | US AC | UNIV AC |
One (1) Power Supply | 8200-1 | 8201-1 | 8206-1 | 8205-1 | 8220-1 | 8226-1 | 8225-1 | 8230-0 | 8235-0 | 8240-1 | 8240-2 |
One (1) Power Supply with Dying Gasp Support | - | - | - | - | - | - | - | 8230-1 | 8235-1 | 8241-1 | 8241-2 |
Two (2) Power Supplies | 8200-2 | 8201-2 | 8206-2 | 8205-2 | 8220-2 | 8226-2 | 8225-2 | - | - | 8245-111* | 8245-112* |
Three (3) Power Supplies | 8200-3 | 8201-3 | 8206-3 | 8205-3 | - | - | - | - | - | - | - |
Spare Power Supply | 8200-9 | 8201-9 | 8206-9 | 8205-9 | 8220-9 | 8226-9 | 8225-9 | - | - | - | - |
23" Rack Mounting Kit | 8091-2 | 8091-2 | 8091-2 | 8091-2 | 8092-2 | 8092-2 | 8092-2 | - | - | - | - |
Blank Module Panel | 8090-0 | 8090-0 | 8090-0 | 8090-0 | 8090-0 | 8090-0 | 8090-0 | 8090-0 | 8090-0 | - | - |
Wall Mounting Hardware Kit | - | - | - | - | - | - | 8249-0 | 8249-0 | 8249-0 | 8249-0 | |
1U 19" Rack Mount Shelf | - | - | - | - | - | - | - | 8260-0 | 8260-0 | 8260-0 | 8260-0 |
DIN Rail Mounting Kit | - | - | - | - | - | - | - | - | 8250-0 | 8250-0 |
When ordering a Wide Temperature chassis, add a W to the end of the part number. For example:8230-1W
Consult factory for extended temperature (-40 to +75º C) models.
* Click on part number for complete ordering information on the 1-Slot Redundant Power Chassis with Power over Ethernet